Create an order in the client portal, pick the tests you need, and print an accession slip for the shipment. Pricing is on screen before you commit.
Third-party purity, identity and safety testing for research peptide vendors, from a US laboratory. Identity is confirmed by LC-MS/MS mass measurement and printed on the certificate, not inferred from retention time.
Accession number
Access code
This is live. It queries the laboratory's own record, the same way your customer's phone does after scanning the QR code on a vial.
The measurement is the product
Every figure we print names its method, its replicate count and its relative standard deviation, and resolves to a record your customer can check without going through you.
Every order includes the verification page, QR code and custody record at no extra charge. Every quantitative result is the mean of replicate runs reported with its RSD, never a single injection. Full instrument and method detail is on the methods and scope page.
Fentanyl & Analogs Screen
LC-MS/MS targeted MRM, 50 ng/mL cutoff
LC-MS/MS Identity Confirmation
LC-MS/MS ESI+ mass confirmation
Stability re-test, 30 day
Purity and content re-run against the day-zero result
BAC Water Verification
pH, benzyl alcohol by HPLC, endotoxin
Raw Powder Purity (RP-HPLC)
RP-HPLC 214 nm purity of bulk powder
Sterility Screen (qPCR)
qPCR microbial DNA screen; rapid, not compendial USP <71>
Purity + LC-MS Identity
RP-HPLC 214 nm + LC-MS/MS identity
Endotoxin (USP <85>)
Kinetic chromogenic LAL
Heavy Metals (ICP-MS)
ICP-MS, USP <233> screening limits
Unit-to-Unit Variance (3 extra vials)
Content assay on three more vials, each reported, with mean and RSD
Stability program, 30/60/90 day
30/60/90 day timepoints, each issuing its own certificate
Full QC Panel
Purity, identity, content, endotoxin, metals, sterility, fentanyl
Full Release Panel
Everything in the QC panel plus TFA, residual solvents, closure integrity, solubility and unit-to-unit variance
| Test | Method |
|---|---|
| Fentanyl & Analogs Screen | LC-MS/MS targeted MRM, 50 ng/mL cutoff |
| LC-MS/MS Identity Confirmation | LC-MS/MS ESI+ mass confirmation |
| Stability re-test, 30 day | Purity and content re-run against the day-zero result |
| BAC Water Verification | pH, benzyl alcohol by HPLC, endotoxin |
| Raw Powder Purity (RP-HPLC) | RP-HPLC 214 nm purity of bulk powder |
| Sterility Screen (qPCR) | qPCR microbial DNA screen; rapid, not compendial USP <71> |
| Purity + LC-MS Identity | RP-HPLC 214 nm + LC-MS/MS identity |
| Endotoxin (USP <85>) | Kinetic chromogenic LAL |
| Heavy Metals (ICP-MS) | ICP-MS, USP <233> screening limits |
| Unit-to-Unit Variance (3 extra vials) | Content assay on three more vials, each reported, with mean and RSD |
| Stability program, 30/60/90 day | 30/60/90 day timepoints, each issuing its own certificate |
| Full QC Panel | Purity, identity, content, endotoxin, metals, sterility, fentanyl |
| Full Release Panel | Everything in the QC panel plus TFA, residual solvents, closure integrity, solubility and unit-to-unit variance |
Four things that are structural rather than promised. Each one is enforced by the system that issues the certificate.
Every released COA is rendered once, fingerprinted with SHA-256, and stored immutably. Corrections issue as new versions with full revision history. Certificates are never edited.
Each certificate carries a QR code and an access code. Anyone holding a vial can confirm the COA is genuine in ten seconds, served by the laboratory rather than the vendor.
Every step from receiving to release is logged automatically in an append-only record you can see in the portal. Nothing moves without a trace.
Results are released only by the Technical Director, never by the analyst who entered them. The rule is enforced by the database, not by policy.
Four steps from your bench to your customer's phone. Every one of them leaves a record.
Swipe to see each step
Step 01 of 04
Create an order in the client portal, pick the tests you need, and print an accession slip for the shipment. Pricing is on screen before you commit.
Storefront API
One script tag renders your live certificate data on your own storefront. The panel is served from our infrastructure, so your customer is reading the laboratory rather than reading you. No other testing laboratory in this market offers it.
You cannot filter it, reorder it, or hide a failing result. That is what makes it worth anything to the person reading it.
Live on this page, right now
This is the real widget calling the real API, not a screenshot. If it were broken, you would be looking at it broken.
Chemistry is targeted at five days from receipt, and the measured median is published once we have enough released work. Compendial USP <71> sterility needs a 14-day incubation: you receive an interim certificate with sterility marked pending, and the final certificate replaces it under the same accession and QR code.
No. A correction issues as a new version with the reason printed on it; the earlier version stays verifiable and is marked superseded. Neither you nor we can unpublish a released certificate.
You, and anyone holding the certificate's access code. Your public vendor page and storefront widget are off until you turn them on.
Not yet. The laboratory is built for ISO/IEC 17025 and will apply for accreditation once it is operating. No result is described as accredited until the scope is granted, and the certificate number and scope will be printed on every certificate from then on.
It describes the vials you sent. We did not select them, so it cannot show that they represent the whole lot, and it does not establish suitability for human or veterinary use.
Reserve founding pricing and capacity before we open. Two minutes, no commitment.
Reserve my placeOne email when the laboratory starts accepting samples. Unsubscribe any time.